Operating Manual
Programmable Controller
LC6
1.951.5220-V2 06/13
JULABO GmbH
77960 Seelbach / Germany
Tel. +49 (0) 7823 / 51-0
Fax +49 (0) 7823 / 24 91
www.julabo.de
Vista de página 0
1 2 3 4 5 6 ... 49 50

Resumo do Conteúdo

Página 1 - Operating Manual

19515220-V2.DOC 26.07.2013 Operating Manual Programmable Controller LC6 1.951.5220-V2 06/13 JULABO GmbH 77960 Seelbach / Germa

Página 2

Operator responsibility – Safety recommendations 10 Safety installations according to IEC 61010-2-010: Excess temperature protection adjustable fr

Página 3

11 Operating instructions 3. Safety notes for the user 3.1. Explanation of safety notes In addition to the safety warnings listed, warnings are p

Página 4

Safety notes for the user 12 attachment.  Observe the limited working temperature range when using plastic bath tanks.  Do not stay in the area be

Página 5 - 1. Intended use

13 4. Operating controls and functional elements 1 Mains power switch, illuminated 2 Start / stop key 3 Working temperature T1 4 Working tempera

Página 6

Operating controls and functional elements 14 19 SF Socket for safety sensor 20 INT Socket for internal measurement and control sensor 21 EXT Sock

Página 7

15 5. Operating procedures 5.1. Installation  The unit should be set up at a dry location.  Place the unit in an upright position and do

Página 8

Operating procedures 16 5.3. Connecting the temperature sensors To avoid error message and safety shutdown (see page 40), attach sensors “SF” and

Página 9

17 5.5. Applications Controlling an open bath with a direct heating device and internal control:  A heating device is used to heat the bath fluid.

Página 10

Operating procedures 18 Controlling an open bath with an indirect heating device and internal control:  The bath fluid is heated with a device prov

Página 11 - Operating instructions

19 6. Operating procedures 6.1. Power connection Caution:  Only connect the unit to a power socket with earthing contact (PE – protective earth)!

Página 12

2 Congratulations! You have made an excellent choice. JULABO thanks you for the trust you have placed in us. This operating manual has been designe

Página 13 - Control: intern

Manual operation 20 7. Manual operation 7.1. Start - Stop Start:  Press the start/stop key . The MULTI-DISPLAY (LED) indica

Página 14 - STAND-BY

21 Selecting the working temperature:  Press the setpoint key and then enter .  Press the setpoint key and then enter . 7.3. Warning fun

Página 15 - 5. Operating procedures

Manual operation 22 7.4. Setting the safety temperature (with shutdown function) +  (excess temperature protection)  Press the key t

Página 16

23 7.5. Internal / external control ext. Pt100 The programmable controller offers the possibility of internal temperature control in a

Página 17

Menu functions 24 8. Menu functions  Press the MENUE key to enter the menu level.  Use the up/down cursor keys to select the desired submenu

Página 18

25 8.1. Configuration By means of the configuration functions, operation of the programmable controller can be optimized for the current applica

Página 19 - 6. Operating procedures

Menu functions 26 Note: Requirement for an identification of the controlled system:  The programmable controller must heat to a setpoint temperatu

Página 20

27 Autostart Note: The programmable controller has been configured and supplied by JULABO according to N.A.M.U.R. recommendations. This means for t

Página 21 -   

Menu functions 28 8.2. Control parameters Xp = When performing an identification for the controlled system (temperature applications sy

Página 22

29 8.3. Start of a profile 1. 2. The start menu of the programmable programmer allows calling up and defined starting of one of s

Página 23

3 TABLE OF CONTENTS Operating manual ...

Página 24 - 8. Menu functions

Menu functions 30 Example: hour.min 6:00 h  When selecting the parameter time, a new menu level is called up for entry of the star

Página 25

31 8.3.1. Interrupting a profile Interrupting a profile: Press the start/stop key to interrupt or restart a profile. The setpoint and time

Página 26

Menu functions 32 8.4. Integrated programmer The integrated programmer allows any desired temperature program sequences to be realized. Such a temp

Página 27

33 Examples: Profile No. 1 Step Setpoint Time Edit Compile profiles:  A flashing segment indicates that a number need

Página 28

Menu functions 34 Delete  A flashing segment indicates that the respective profile number needs to be entered in which one or more consecut

Página 29

35 8.5. Analog inputs/outputs or This submenu enables setting of the input and output values for the programmer input and the

Página 30

Menu functions 36 0 V0 mA20 mA4 mA10 °C 210 °C197 °C 202 °C 5 K 200 K Examples: lowest temperature value: 10 °C highest temperatur

Página 31

37 Example:  Setting a temperature of 50 C on the external programmer! The value adjusted and set on the external programmer is displayed in

Página 32

Menu functions 38 8.6. Limits When operating the programmable controller under external control, band limiting is active. The preset value determi

Página 33

39 8.8. Sensors ATC - Absolute Temperature Calibration  Select the submenu „Temp.Sensor“ with enter .  Select the desired option with the up

Página 34

4 8.5. Analog inputs/outputs ... 35 8.6. Limits

Página 35

Troubleshooting guide / Error messages 40 9. Troubleshooting guide / Error messages + Whenever the microprocessor electronics registers a failure,

Página 36

41 10. Electrical connections Notice: Use shielded cables only. The shield of the connecting cable is electrically connected to the plug housing.

Página 37

Electrical connections 42 123456 REG+E-PROG Programmer input / temperature recorder output (31) Analog inputs / outputs see page 35 Pin Signal

Página 38

43 AK123STAND-BY AK123 STAND-BY input (33) (for external emergency switch-off) Pin assignment: Pin Signal 1 n

Página 39

Remote control 44 Control connector (35) The connector may be used with solenoid valves. Line voltage: 230 V / max. 1.25 A 115 V / max. 1.2

Página 40

45 11.2. Communication with a PC or a superordinated data system Suitable terminal programs for communicating with a PC are:  MS-Windows - TERMI

Página 41 - 10. Electrical connections

Remote control 46 11.3. List of commands When the RS485 interface is used, the instrument address stands in front of each command (Axxx_). in-comman

Página 42 -

47 Command Parameter Response of programmable controller in_mode_04 none Internal/external temperature control: 0 = Temperature control with Pt100

Página 43

Remote control 48 Command Parameter Response of circulator out_mode_02 2 Continual identification of controlled system whenever a new setpoint is to

Página 44 - 11. Remote control

49 11.4. Status messages / error messages The programmable controller sends data (including error messages) only when the computer sends a query.

Página 45

5 Operating manual 1. Intended use Fulfilling its principle task, reliable temperature control and measurement, the LC6 temperature controller also

Página 46

Cleaning / repairing the unit 50 12. Cleaning / repairing the unit Caution: Improper maintenance or repair can result in electric shock or damage t

Página 47

Operator responsibility – Safety recommendations 6 If you have any questions concerning the operation of your unit or the information in this manual,

Página 48

7 1 Warning label W00: Colors: yellow, black Danger area. Attention! Observe instructions. (operating manual, safety data sheet) 2 or Mandat

Página 49

Operator responsibility – Safety recommendations 8 2.2. EC Conformity The products described in the operating instructions conform to the requireme

Página 50

9 2.4. Technical specifications LC6 Adjustable temperature range °C -100 ... 400 Display accuracy % ±0.5 ±1Digit Temperature stability °C